SPECIFICATIONS
Load Rating: 20 amps @ 120 volts.
Power Requirement (no load): 20 watts.
Surge Let-Through Voltage (6000-volt surge): 0 volts
UL 1449 Adjunct Classification Test Results: 1000 surges, 6000 volts, 3000 amps, B3 pulse; Measured suppressed voltage: 170 volts; no failures
Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818)
EMI/RFI Filter, Normal Mode (50-ohm load): 40 dB @ 100 kHz; 50 dB @ 300 kHz; 50 dB @ 3 MHz; 50dB @ 30 MHz
EMI/RFI Filter, Common Mode (50-ohm load): 18 dB @ 300 kHz; 30 dB @ 1 MHz; 50 dB @ 5 MHz; 50 dB @ 20 MHz
Maximum Applied Surge Voltage: 6000 volts*
Maximum Applied Surge Current: Unlimited, due to current limiting*
Maximum Applied Surge Energy: Unlimited, due to current limiting*
Endurance (C62.41-1991 Category B3 pulses): 1 kV>500,000; 3 kV>10,000; 6 kV>1000
Control Inputs: Momentary Switch, Latching Switch, Contact Closure or 5-30 Vdc
Input Control Current: 3 mA
DC Voltage Output: 12 Vdc, 40 mA maximum load
Auxiliary Relay Output: 1 amp, 30 Vdc
Delay Times: 0-40 seconds
Dimensions: 3.5" H x 19.0" W x 10.5" D (8.9 x 48.3 x 26.7 cm)
Weight: 16 lbs (7.3 kg)
Temperature Range: 5º to 35º C
Humidity Range: 5% to 95% R.H., non-condensing.
Agency Listings: ETL and cETL (UL 1449, 2nd edition; CSA C22.2 No.8-M1986, R2000)
*1.2 x 50 µs pulse, industry standard combination wave surge, as per IEEE C62.41
Specifications subject to change without notice. SurgeX is a division of Electronic Systems Protection, Inc.
This product, including its components and/or processes carried out thereby, are covered by one or more of the following: U.S. Pat. No. 4,870,534. 4,870,528. 6,728,089. 6,744,613. 7,068,487. Can. Pat. No. 1,333,191. 1,332,439. Other Patents Pending. |
FEATURES
- Magnetic shielding steel enclosure
- 9' grounded 3-wire #12 line cord
- Three sequenced banks of four receptacles with combined load of 20 amperes
- Two receptacles always on
- Control output for fourth external bank
- Can be used to control other SurgeX surge eliminators and power conditioners, or daisy-chained with other SEQs
- Easy setup and programming
- LCD display
- Setup stored in nonvolatile memory
- Provides continual display of AC line voltage
- Accommodates any type of control input
- DC voltage or contact closure feedback to
Crestron, AMX or similar control devices.
- Output to drive up to four status LEDs
- Advanced Series Mode surge protection
- COUVS catastrophic over/under-voltage shutdown
- SurgeX ICE inrush current elimination technology
- Advanced Impedance Tolerant EMI/RFI filtering
- Thermal circuit breaker overload protection
- 10-year warranty
- Made in U.S.A.
TECHNICAL DESCRIPTION
The SEQ shall be a two-rack-space unit in a magnetic shielding steel enclosure. It shall operate from 120 volts AC and have a 9-foot, grounded, 3-wire #12 line cord. There shall be 12 grounded AC receptacles in three banks of four on the rear panel, each bank sequenced from the previous bank by an adjustable 0 - 40 second delay, and two receptacles always on. There shall be a back-lit LCD display that shows unit status and AC line voltage, and two
screwdriver adjustments to program the unit. Overall dimensions shall be 3.5” H x 19” W x 10.5” D. Weight shall be 16 pounds.
The SEQ shall have a load rating of 20 amps at 120 volts, a self-test circuit with visual indicator and provide EMI/RFI filtering, inrush current elimination and catastrophic over/under-voltage shutdown. It shall meet Federal Grade A, Class 1, Mode 1 guidelines for powerline surge suppressors and withstand at least 1000 occurrences of surge pulse voltages up to 6000 volts.
|